EXPERIMENTS REGARDING THE EFFECTS OF ISOTOPIC SEPARATION IN PEM ELECTROLYSERS Print

EXPERIMENTS REGARDING THE EFFECTS OF ISOTOPIC SEPARATION IN PEM ELECTROLYSERS

 

 

Mariana Iliescu*, Mihai Varlam, Roxana Elena Ionete, Mihai Culcer, Mihai Balan

 

 

National Institute for Research and Development for Cryogenic and Isotopic   Technologies - ICIT Rm. Valcea, Uzinei Street no.4; P.O. Box 7 Râureni, 240050, Rm.Vâlcea, Romania

 

 

ABSTRACT

 

The paper deals with the first experiments conducted in the National Center for Hydrogen and Fuel Cell, in order to reveal the isotope separation effect in water electrolysis. Four water compositions having deuterium content in the range of natural (144 ppm) to 2%, were used to feed a PEM electrolizer, and the deuterium content of the evolving hydrogen was analyzed, revealing a slightly depletion.

 

KEYWORDS: PEM electrolyzer, water electrolysis, isotope separation



*Corresponding authors: Mariana Iliescu, e-mail: This e-mail address is being protected from spambots. You need JavaScript enabled to view it , phone:0040 250 732744, fax:0040 250 732746